Open Access Open Access  Restricted Access Subscription Access

Review on Summing Up Remote Case Endoscopy Video Part in Mild of Between Casing Primary Similitude File

Mrs. Ridhdhi Marmik Naik

Abstract


Wireless Capsule Endoscopy (WCE) is a safe and painless innovation that permits total investigation of the little inside. In every assessment, the visual review of various video outlines in WCE makes a tedious undertaking in any event, for the accomplished doctors. The presence of excess edges in WCE is the significant justification for the delayed audit time. Screening the WCE outlines into instructive and non-enlightening ones or disposing of the casings ruined by gastric squeeze or air pockets, because the textural includes alone is not a suitable method for lessening the survey time. The overt repetitiveness among the edges could be distinguished as more attainable by utilizing between outline similitude’s as opposed to assessing the consistency of textural highlights. The target of this work is to sum up the WCE video given the outline Underlying Similitude File (SSIM). In the proposed technique for summing up the WCE video, the SSIM between back-to-back outlines is processed. The edges between outline SSIM more prominent than a limit are viewed as comparative or repetitive. Non-repetitive edges and one casing from each excess gathering are coordinated to shape the WCE outline. The limit of SSIM which recognizes excess edges is fixed by subjectively assessing various arrangements of repetitive casings with assorted SSIM values from various areas of different WCE recordings. The proposed technique achieved a level of decrease in several casings of 19.01 %± 0.1901 on five arrangements of WCE example for an edge SSIM of 0.98.


Full Text:

PDF

References


. Maieron, A., D. Hubner, B. Blaha, C. Deutsch, T. Schickmair, A. Ziachehabi, E. Kerstan, P. Knoflach and R. Schoefl, 2004. “Multicenter retrospective evaluation of capsule endoscopy in clinical routine,” Endoscopy, 36: 864-868.

. Jessie Westerhof, Jan J. Koornstra, Rinse K. Weersma, 2009. “Can we reduce capsule endoscopy reading times?,” Gastrointestinal Endoscopy, 69: 497-502.

. Iakovidis, D.K., E. Spyrou, D. Diamantis, 2013. "Efficient homography-based video visualization for wireless capsule endoscopy," 2013 IEEE 13th International Conference on Bioinformatics and Bioengineering (BIBE), pp: 1-4.

. Chu, X., C.K. Poh, L. Li, K.L. Chan, S. Yan, W. Shen, T.M. Htwe, J. Liu, J.H Lim, E.H. Ong, K.Y. Ho, 2010. "Epitomized summarization of wireless-capsule endoscopic videos for efficient visualization, "Med Image Computing Computer Assist Interv., 6362: 522-529.

. Zhuoli Dong, Ziqiang Wang, 2011."Screening of capsule endoscopy redundant image based on image motion model by block matching," Electrical and Control Engineering (ICECE), International Conference on, pp: 5436 -5439.

. Piotr, M., Szczypiński, Ram D. Sriram, Parupudi V.J. Sriram, D. Nageshwar Reddy, 2009. "A model of deformable rings for interpretation of wireless-capsule endoscopic videos," Medical Image Analysis, 13(2): 312-324.

. Baopu Li, Meng, M.Q.-H., 2011. "Comparison of several image features for WCE video abstract," International Conference on Intelligent Robots and Systems (IROS), 2011 IEEE/RSJ, pp: 2090-2095.

. Hyun-Gyu Lee, Min-Kook Choi, Byeong-Seok Shin, Sang-Chul Lee, 2013. “Reducing redundancy in wireless capsule endoscopy videos,” Computers in Biology and Medicine, 43: 670-682.

. Iakovidis, D.K., S. Tsevas, A. Polydorou, 2010. "Reduction of capsule endoscopy reading times by unsupervised image mining, "Computerized Medical Imaging and Graphics, 34: 471-478.

. Gallo, G., E. Granata, G. Scarpulla, 2009. "Wireless Capsule Endoscopy video segmentation," IEEE International Workshop on Medical Measurements and Applications, 2009. MeMeA2009.pp: 236-240.


Refbacks

  • There are currently no refbacks.