Enhanced Earth Fault Detection in Power Systems Using Neutral Voltage Displacement Method

Hachimenum Nyebuchi Amadi, Onyebuchi Nelson Igbogidi, Order Nornubari Kor

Abstract


The zeal to swiftly detect and isolate a faulty section of the power system is very important if the system is to be described as a reliable one. In achieving this a prototype Distribution Board Earth Fault Detection System (DBEFDS) was designed and constructed based on single-phase scenario using Neutral Voltage Displacement (NVD) method. This was done because the system is symmetrical. Neutral Voltage Displacement (NVD), Directional Overcurrent (DO), and Distance Protection (DP) in fault detection algorithm were also compared in terms of time response during fault. At the maximum distance of 50km, neutral voltage displacement detected fault at 1.10 seconds while distance protection and directional overcurrent detected fault at 0.83 seconds and 0.55 seconds respectively. Faults at 0km, 5km, 10km, 15km, 20km, 25km, 30km, 35km, 40km, 45km, and 50km were detected at 0.10s, 0.20s, 0.30s, 0.40s, 0.50s, 0.60s, 0.70s, 0.80s, 0.90s, 1.00s and 1.10s respectively, using neutral voltage displacement method. Faults at 0km, 5km, 10km, 15km, 20km, 25km, 30km, 35km, 40km, 45km, and 50km were detected at 0.08s, 0.15s, 0.23s, 0.30s, 0.38s, 0.46s, 0.53s, 0.60s, 0.68s, 0.75s and 0.83s respectively, using distance protection method. Faults at 0km, 5km, 10km, 15km, 20km, 25km, 30km, 35km, 40km, 45km, and 50km were detected at 0.05s, 0.10s, 0.15s, 0.20s, 0.25s, 0.30s, 0.40s, 0.45s, 0.50s and 0.55s respectively, using directional over current method. It was noted that single-line-to-ground fault recorded 500Ω in dry land and 300Ω in wet land and by this, earth fault was detected at 0.10s within the premises using neutral voltage displacement method. This method has proven to provide earth fault detection time for the safety of lives and equipment as provided in IEEE regulation.


Full Text:

PDF

References


Obukoeroro., J., & Hilary., U. (2021). Evaluating the Geotechnical and Electrical Properties of Soil Samples around Delta State Polytechnic Ozoro Nigeria. Applied Journal of Physical Science, 3(1), 21027.

Oyeleye M., O. (2019). Design of Distribution Board Unit for A Business Focus. European Journal of Electrical and Computer Engineering, 3(5), 11-19.

Samuel, I. A. (2017). Prediction of voltage collapse in electrical power system networks using a new voltage stability index. International Journal of Applied Engineering Research, 12, 190-199.

Zeng, X., Wang, Z., Yu, K., Peng, H., Zhuo, C., & Zhou, D. (2022). Arc suppression device for actively reducing grounding fault phase voltage based on phase power supply feedback in a distribution network and its application. High Voltage Engineering, 48, 3356–3366.

Abdulkareem, A. (2016). The use of three-phase fault analysis for rating circuit breakers on Nigeria 330 kV transmission lines. Journal of Engineering and Applied Sciences, 11, 2612-2622.

Adekitan, A. I. (2018). Supply instability induced torque variations of a three-phase asynchronous motor. International Journal of Mechanical Engineering and Technology (IJMET), 9, 572-583.

Chen, H., Tian, X., Gao, C., Zheng, S., & Yan, C. (2019). Research overview on fault location for DC microgrid. Guang Dong Electric Power, 32, 44–51.

Hurtado, Z. Y. M. (2015). A review on location, detection, and fault diagnosis in induction machines. Journal of Engineering Science and Technology Review, 8, 185-189.

Karakoulidis, K. (2015). The temperature measurement in a three-phase power transformer under different conditions. Journal of Engineering Science and Technology Review, 8, 19-23.

Lazzaretti, A. E. (2017). An integrated monitoring system and automatic data analysis to correlate lightning activity and faults on distribution networks. Electric Power Systems Research, 153, 66-72.


Refbacks

  • There are currently no refbacks.