Open Access Open Access  Restricted Access Subscription Access

A Physics-Driven Smartphone Framework for Remote Uroflowmetry Using Computer Vision

Ramya B N, Bhavana Mohandas sangalad, Bhargavi naik, Anusha K

Abstract


Uroflowmetry is routinely used in urology to characterize urinary flow during voiding and to support assessment of lower urinary tract dysfunction. In conventional testing, the patient uses a dedicated collection device equipped with a calibrated transducer. This arrangement generally limits testing to clinical facilities, adds equipment and maintenance requirements, does not retain a direct visual record of the void, and may influence normal voiding behavior. This study presents a physics-informed video analysis framework in which a three-tier computer-vision architecture is used instead of dedicated flow-rate acquisition hardware. A smartphone recording is scaled using a fixed 26 cm physical reference and passed through a processing pipeline comprising background subtraction (MOG2), region-of-interest (ROI) locking, width-based gating, morphological cleanup, vertical dilation, and geometric (aspect-ratio) filtering to distinguish the stream from the surrounding body, hands, and background. Velocity tracking and volume normalization convert the isolated stream into a clinically meaningful flow curve, from which metrics including peak flow rate (Qmax), average flow rate, flow time, voiding time, time to Qmax, and hesitancy are derived. A confidence-weighted ensemble fuses top- and side-view recordings for improved robustness. The resulting workflow is implemented as an end-to-end clinical web platform: a React-based frontend for patient intake, video upload, and report viewing; a FastAPI backend providing JWT-authenticated, role-based endpoints for patient management, analysis orchestration, and report/email delivery; and cloud-based media storage. This work is presented as a proposed and implemented system architecture; quantitative validation results, accuracy figures, and dataset-level evaluation are not yet available and are identified as required future work. The principal contribution is a smartphone-based acquisition approach that avoids dedicated uroflow transducer hardware that extends existing AI-based uroflow curve-classification research, which assumes a transducer-derived signal, into the signal-acquisition stage itself.


Full Text:

PDF

References


H.-H. Huang, P.-Y. Cheng, and C.-Y. Tsai, “Exploring artificial intelligence in functional urology: A comprehensive review,” Urological Science, vol. 36, no. 1, pp. 2–10, 2025, doi: 10.1097/us9.0000000000000057.

“Machine Learning for Uroflow Analysis” (“Paper1 Study”), as referenced in project source material, 2024. [DATA REQUIRED — this source could not be independently verified; a matching publication with the described SVM/neural-network methodology and this exact title was not found. Do not include in a final submission until the correct source is confirmed and re-cited.]

L. E. Chew, J. H. Hannick, L. L. Woo, J. K. Weaver, and M. S. Damaser, “The future of urodynamics: Innovations, challenges, and possibilities,” Neurourology and Urodynamics, vol. 45, no. 2, pp. 293–298, 2026 (published online 14 May 2025), doi: 10.1002/nau.70074.

M. Plata, J. Azuero, F. Daza, M. Rojas-Rivillas, V. Garcia, A. Gutierrez, S. Cañar, T. Rodriguez, S. Gomez, and L. Giraldo, “AI-based platform for automated uroflowmetry curve morphology classification,” presented at the International Continence Society (ICS) / EUS Annual Meeting, Abstract 557, Sept. 19, 2025.

OpenCV Development Team, OpenCV Library Documentation — Background Subtraction (MOG2) and Contour Analysis. [DATA REQUIRED: access date/URL, as cited in project source material]

S. Ramírez, FastAPI: High-Performance Web Framework for Building APIs with Python, FastAPI Documentation. [DATA REQUIRED: access date/URL]

Meta Open Source, React 19 — A JavaScript Library for Building User Interfaces, React Documentation. [DATA REQUIRED: access date/URL]

M. J. Drake et al., Fundamentals of Urodynamic Practice — Uroflowmetry Principles and Interpretation. [DATA REQUIRED: publisher, edition, year, page numbers]

P. Virtanen et al., “SciPy 1.0: Fundamental algorithms for scientific computing in Python,” Nature Methods, vol. 17, pp. 261–272, 2020, doi: 10.1038/s41592-019-0686-2. (Note: this is the well-known, independently verifiable SciPy 1.0 paper; confirm it is indeed the source your project intended to cite before finalizing.)

Project Repository README, “Uroflow Computer Vision Analysis System” (clean-doc_ag / Dockothon). [DATA REQUIRED: repository URL, access date]


Refbacks

  • There are currently no refbacks.